The Rigel SafeTest 60 is a robust, reliable and dedicated medical safety analyzer. It is ideal for testing high volumes of medical and laboratory equipment that does not require patient lead testing, such as beds, hoists, infusion pumps, CPAP’s and centrifuges etc.
With a large colour display and a colour-coded user interface, it’s easy to select the required tests with a single key press, whilst a fast step-through of the test routine makes the testing process speedy and dependable.
Whilst small, the SafeTest 60 includes a range of safety tests to enable compliance with a range of international safety standards, including leakage testing to IEC 60601, 62353, 61010 and NFPA-99, earth bond testing to 62353, 61010 and NFPA-99, and insulation testing to IEC 62353.
Earth Continuity
|
|
---|---|
Method
|
2 wire ZAP technique.
|
Test Current
|
>±200mADC into 2Ω
|
Max Test Voltage
|
4-24Vrms o/c
|
Measuring Range
(low range) |
0.001 – 0.999Ω / 0.001Ω resolution
|
Measuring Range
(mid range) |
1.00 – 9.99Ω / 0.01Ω resolution
|
Measuring Range
(high range) |
10.0 – 19.9Ω / 0.1Ω resolution
|
Accuracy
|
± 1% of value, ± 5mΩ
|
Circuit Protection
|
Test inhibited if ≥30VAC or DC at 4mm inputs
|
Insulation Resistance (Non US versions only)
|
|
---|---|
Measurement
|
EUT to Earth
|
Voltage
|
500VDC @1mA
|
Maximum O/C Voltage
|
<600VDC
|
Range
|
100K - 20MΩ ± 5% ± 2 digits
|
Resolution
|
0.01MΩ
|
Short circuit current
|
<2mA
|
Powered Leakage Measurements
|
|
---|---|
IEC 62353
|
Equipment Leakage (Direct)
|
IEC / AAMI 60601
|
Earth + Enclosure Leakage
|
NFPA-99
|
Ground + Chassis Leakage
|
IEC 61010
|
Touch Leakage, Touch Voltage
|
Test Voltage
|
Mains Supply Voltage
|
Measuring Range
|
0.1μA to 9999μA
|
Accuracy
|
± 2%, ± 5µA
|
Mains Reversal
|
Softkey
|
Single Fault Conditions
|
Open neutral via softkey
Open earth via softkey |
Frequency Response
|
IEC 60601 - 62353, NFPA-99 and IEC 61010
|
Voltage Measurement
|
|
---|---|
Application
|
L-N, L-E, N-E and touch voltage (IEC 61010)
|
Range
|
0.0V - 300VAC
|
Resolution
|
0.1V
|
Accuracy
|
±2% ± 2 digits (between 10V - 270VAC)
|
Mains frequency
|
45.0 - 66.0Hz
|
Resolution
|
0.1Hz
|
Accuracy
|
Unspecified
|
EUT Load Current Measurement
|
|
---|---|
Range
|
0.0A - 20.0A
|
Resolution
|
0.1A
|
Accuracy
|
±5% ± 2 digits
|
Power Source
|
|
---|---|
Maximum current rating
|
20A @ 120V / 16A @ 230V
|
Duty cycle
|
15A to 20A, 5 min, on/5 min, off
10A to 15A, 7 min, on/3 min, off 0A to 10A, continuous
|
Mains power
|
90-264V 46-64Hz
|
General Specification
|
|
---|---|
Weight
|
1.1kg / 2.5lbs (unit)
2.2kg / 5lbs (complete with accessories) |
Size (L x W x D)
|
225 x 150 x 100mm / 9 x 6 x 4"
|