Rigel SafeTest 50 Electrical Safety Analyzer
Rigel SafeTest 50 Electrical Safety Analyzer Rigel SafeTest 50 Electrical Safety Analyzer Rigel SafeTest 50 Electrical Safety Analyzer
SALES LEAD TIME IS 7 DAYS. CALL FOR PRICING
Brand: Rigel Medical
Product Code: SafeTest 50
Availability: In Stock
SALES LEAD TIME:  14 DAYS
WARRANTY: One Year
ACCESSORIES INCLUDED: Soft carrying case, Test Lead, Power Cord, Instruction Manual, Calibration Certificate
 
OVERVIEW:

The Rigel SafeTest 60 is a robust, reliable and dedicated medical safety analyzer. It is ideal for testing high volumes of medical and laboratory equipment that does not require patient lead testing, such as beds, hoists, infusion pumps, CPAP’s and centrifuges etc.

With a large colour display and a colour-coded user interface, it’s easy to select the required tests with a single key press, whilst a fast step-through of the test routine makes the testing process speedy and dependable.

Whilst small, the SafeTest 60 includes a range of safety tests to enable compliance with a range of international safety standards, including leakage testing to IEC 60601, 62353, 61010 and NFPA-99, earth bond testing to 62353, 61010 and NFPA-99, and insulation testing to IEC 62353.

SPECIFICATIONS:
Earth Continuity
Method
2 wire ZAP technique.
Test Current
>±200mADC into 2Ω
Max Test Voltage
4-24Vrms o/c
Measuring Range
(low range)
0.001 – 0.999Ω / 0.001Ω resolution
Measuring Range
(mid range)
1.00 – 9.99Ω / 0.01Ω resolution
Measuring Range
(high range)
10.0 – 19.9Ω / 0.1Ω resolution
Accuracy
± 1% of value, ± 5mΩ
Circuit Protection
Test inhibited if ≥30VAC or DC at 4mm inputs
Insulation Resistance (Non US versions only) 
Measurement
EUT to Earth
Voltage
500VDC @1mA
Maximum O/C Voltage
<600VDC
Range
100K - 20MΩ ± 5% ± 2 digits
Resolution
0.01MΩ
Short circuit current
<2mA
Powered Leakage Measurements
IEC 62353
Equipment Leakage (Direct)
IEC / AAMI 60601
Earth + Enclosure Leakage
NFPA-99
Ground + Chassis Leakage
IEC 61010
Touch Leakage, Touch Voltage
Test Voltage
Mains Supply Voltage
Measuring Range
0.1μA to 9999μA
Accuracy
± 2%, ± 5µA
Mains Reversal
Softkey
Single Fault Conditions
Open neutral via softkey
Open earth via softkey
Frequency Response
IEC 60601 - 62353, NFPA-99 and IEC 61010
Voltage Measurement
Application
L-N, L-E, N-E and touch voltage (IEC 61010)
Range
0.0V - 300VAC
Resolution
0.1V
Accuracy
±2% ± 2 digits (between 10V - 270VAC)
Mains frequency
45.0 - 66.0Hz
Resolution
0.1Hz
Accuracy
Unspecified
EUT Load Current Measurement
Range
0.0A - 20.0A
Resolution
0.1A
Accuracy
±5% ± 2 digits
Power Source
Maximum current rating
20A @ 120V / 16A @ 230V
Duty cycle
15A to 20A, 5 min, on/5 min, off
10A to 15A, 7 min, on/3 min, off
0A to 10A, continuous
Mains power
90-264V 46-64Hz
General Specification
Weight
1.1kg / 2.5lbs (unit)
2.2kg / 5lbs (complete with accessories)
Size (L x W x D)
225 x 150 x 100mm / 9 x 6 x 4"