Search
Browse Categories

"NEW" Fluke PS420 Multi-Parameter Patient Simulator


Price: $2,195.00
Item Number: PS420
WARRANTY: One Year
SALES LEAD TIME: Typical lead time is 14-21 days
ACCESSORIES: Operator Manual, Battery Eliminator, Calibration Certificate

PS420 Multiparameter Patient Simulator

The PS420 Patient Simulator is a handheld, high-performance simulator for testing patient monitors.

Small enough to fit in a pocket, the handy PS420 features a wide variety of simulation capability, including a full range of ECG, respiration, blood pressure, temperature and cardiac output conditions. The tool includes 12-lead ECG, two-channel blood pressure simulation, 35 arrhythmia selections, pacemaker simulation as well as adult and pediatric normal sinus rhythms.

For convenient use, labeled hot keys on the keypad guide users to the most common settings.

FEATURES:
Compact, lightweight, pocketsize
Labeled hot keys for common settings
12-lead ECG
Respiration and temperature selection
Two-channel blood pressure simulation
Optional cardiac output
Adult and pediatric normal sinus rhythms
35 arrhythmia selections
ECG performance waveforms
ST segment levels
ECG artifact
Pacemaker simulation
RS232 serial port for computer control
Battery operated


TECHNICAL SPECIFICATIONS:

ECG:
Normal Rate: 80BPM
ECG Amplitudes:
0.5mv, 1mv, 1.5mv, 2mv
Output Impedance:
500, 1000, 1500, and 2000 ohms for Leads I, II, III
High-Level Output:
1000x Lead II
Selectable Rates:
30 - 300 bpm
Accuracy:
+/- 1%
ECG Waveform Selections: adult or pediatric ECG Waveform

ECG PERFORMANCE WAVEFORMS:
Square Wave:2.0Hz, 0.125 Hz
Pulse:
30, 60, 120 bpm, 60 mS pulse width
Sine Waves:
0.5, 4.0, 10, 40, 50, 60, (1mv Amplitude, lead II)
Triangle Wave:
2.0 Hz

ST SEGMENT ANALYSIS:
Elevated or depressed: -0.8mV to +0.8mV in 1mV steps

ARRYTHMIA SELECTIONS:
PREMATURE BEATS
Atrial (PAC)
Nodal (PNC)
PVC1 LV Focus
PVC1 Early LV Focus
PVC1 R on T LV Focus
PVC2 RV Focus
PVC2 Early RV Focus
PVC2 R on T RV Focus
MULTIFOCAL PVC's
Supraventricular
Atrial Fibrillation (coarse)
Atrial Fibrillation (fine)
Atrial Flutter
Sinus Arrhythmia
Missed Beat
Atrial Tachycardia
Nodal
Supraventricular Tachycardia
VENTRICULAR RHYTHMS:
PVCs 6/minute
PVCs 12/minute
PVCs 24/minute
Frequent Multifocal
Bigeminy
Trigeminy
Pair PVCs
Run 5 PVCs
Run 11 PVCs
Ventricular Tachycardia
Ventricular Fibrillation (coarse)
Ventricular Fibrillation (fine)
Asystole
CONDUCTION DEFECTS:
First degree heart block
Second degree heart block
Third degree heart block
Right bundle branch block
Left bundle branch block

RESPIRATION:
Baseline Impedance: 500, 1000, 1500, 2000 ohms, Leads I, II, and III
Lead Selections: LL or LA
Impedance Variations: 3, 1, 0.5, and 0.2 ohms
Accuracy: +5%
Rates: 15, 20, 30, 40, 60, 80, 100,120, and 0 BPM for Apnea
Accuracy: +2%
Apnea: 12 seconds, 22 seconds, 32 seconds, and continuous

TEMPERATURE:
Compatibility: YSI 400/700 Series
Temperature: 86, 95, 98.6, 104, 107.6 F degrees (30, 35, 37, 40, 42 C degrees)
Temperature Simulation Accuracy: +0.25 C degrees

PACEMAKER:
Pacer Spike Amplitude: 2, 4, 8, and 10mV in Lead II
Accuracy: +5%, lead II
Pacer Spike Duration: 0.1, 0.5, 1, 1.5, 2 ms
Accuracy: +5%
Selections: Asynchronous Pacemaker, Pacer Non-Function, Pacer Non-Capture, Demand Occasional Sinus, Demand Frequent Sinus, AV Sequential

BLOOD PRESSURE CHANNELS:
Dynamic BP waveforms are synchronized with normal sinus rhythm rates and track arrhythmia selections.
Input/Output Impedence: 350 Ohms
Level Accuracy: +1%, +1 mmHg
Exciter Input Limit: + 10V
Exciter Input Frequency Range: DC to 4000 Hz
Transducer Sensitivity: 5 or 40 uV/V/mmHg
Calibrated Rate: 80 bpm normal sinus rhythm
Static Levels BP1: -10, 0, 50, 100, 150, 200, 250 mmHg
Static Levels BP2: -10, 0, 80, 160, 240, 320, 400 mmHg

P1 Channel Selections
Arterial: 120/80
Radial artery: 120/80
Left ventricle: 120/00
Right ventricle: 25/00

P2 Channel Selections
Arterial: 120/80
Radial artery: 120/80
Left ventricle: 120/00
Right atrium (Central Venous): 15/10
Right ventricle: 25/00
Pulmonary artery: 25/10
Pulmonary wedge: 10/2
Left atrium: 14/4

RS-232
RS-232 bi-directional interface 9600 Baud

Power
9 V alkaline battery

Dimensions
6.1" x 3.7" x 1.3"
(15.6 cm x 9.4 cm x 3.4 cm)

Weight
0.9 lb (0.4 kg)