"NEW" Fluke PS420 Multi-Parameter Patient Simulator
|
|
Item Number: PS420
|
WARRANTY: One Year
SALES LEAD TIME: Typical lead time is 14-21 days ACCESSORIES: Operator Manual, Battery Eliminator, Calibration Certificate
PS420 Multiparameter Patient Simulator
The PS420 Patient Simulator is a handheld, high-performance simulator for testing patient monitors.
Small enough to fit in a pocket, the handy PS420 features a wide variety of simulation capability, including a full range of ECG, respiration, blood pressure, temperature and cardiac output conditions. The tool includes 12-lead ECG, two-channel blood pressure simulation, 35 arrhythmia selections, pacemaker simulation as well as adult and pediatric normal sinus rhythms.
For convenient use, labeled hot keys on the keypad guide users to the most common settings.
FEATURES: Compact, lightweight, pocketsize Labeled hot keys for common settings 12-lead ECG Respiration and temperature selection Two-channel blood pressure simulation Optional cardiac output Adult and pediatric normal sinus rhythms 35 arrhythmia selections ECG performance waveforms ST segment levels ECG artifact Pacemaker simulation RS232 serial port for computer control Battery operated
TECHNICAL SPECIFICATIONS:
ECG: Normal Rate: 80BPM ECG Amplitudes: 0.5mv, 1mv, 1.5mv, 2mv Output Impedance: 500, 1000, 1500, and 2000 ohms for Leads I, II, III High-Level Output: 1000x Lead II Selectable Rates: 30 - 300 bpm Accuracy:+/- 1% ECG Waveform Selections: adult or pediatric ECG Waveform
ECG PERFORMANCE WAVEFORMS: Square Wave:2.0Hz, 0.125 Hz Pulse: 30, 60, 120 bpm, 60 mS pulse width Sine Waves: 0.5, 4.0, 10, 40, 50, 60, (1mv Amplitude, lead II) Triangle Wave: 2.0 Hz
ST SEGMENT ANALYSIS: Elevated or depressed: -0.8mV to +0.8mV in 1mV steps
ARRYTHMIA SELECTIONS: PREMATURE BEATS Atrial (PAC) Nodal (PNC) PVC1 LV Focus PVC1 Early LV Focus PVC1 R on T LV Focus PVC2 RV Focus PVC2 Early RV Focus PVC2 R on T RV Focus MULTIFOCAL PVC's Supraventricular Atrial Fibrillation (coarse) Atrial Fibrillation (fine) Atrial Flutter Sinus Arrhythmia Missed Beat Atrial Tachycardia Nodal Supraventricular Tachycardia VENTRICULAR RHYTHMS: PVCs 6/minute PVCs 12/minute PVCs 24/minute Frequent Multifocal Bigeminy Trigeminy Pair PVCs Run 5 PVCs Run 11 PVCs Ventricular Tachycardia Ventricular Fibrillation (coarse) Ventricular Fibrillation (fine) Asystole CONDUCTION DEFECTS: First degree heart block Second degree heart block Third degree heart block Right bundle branch block Left bundle branch block
RESPIRATION: Baseline Impedance: 500, 1000, 1500, 2000 ohms, Leads I, II, and III Lead Selections: LL or LA Impedance Variations: 3, 1, 0.5, and 0.2 ohms Accuracy: +5% Rates: 15, 20, 30, 40, 60, 80, 100,120, and 0 BPM for Apnea Accuracy: +2% Apnea: 12 seconds, 22 seconds, 32 seconds, and continuous
TEMPERATURE: Compatibility: YSI 400/700 Series Temperature: 86, 95, 98.6, 104, 107.6 F degrees (30, 35, 37, 40, 42 C degrees) Temperature Simulation Accuracy: +0.25 C degrees
PACEMAKER: Pacer Spike Amplitude: 2, 4, 8, and 10mV in Lead II Accuracy: +5%, lead II Pacer Spike Duration: 0.1, 0.5, 1, 1.5, 2 ms Accuracy: +5% Selections: Asynchronous Pacemaker, Pacer Non-Function, Pacer Non-Capture, Demand Occasional Sinus, Demand Frequent Sinus, AV Sequential
BLOOD PRESSURE CHANNELS: Dynamic BP waveforms are synchronized with normal sinus rhythm rates and track arrhythmia selections. Input/Output Impedence: 350 Ohms Level Accuracy: +1%, +1 mmHg Exciter Input Limit: + 10V Exciter Input Frequency Range: DC to 4000 Hz Transducer Sensitivity: 5 or 40 uV/V/mmHg Calibrated Rate: 80 bpm normal sinus rhythm Static Levels BP1: -10, 0, 50, 100, 150, 200, 250 mmHg Static Levels BP2: -10, 0, 80, 160, 240, 320, 400 mmHg
P1 Channel Selections Arterial: 120/80 Radial artery: 120/80 Left ventricle: 120/00 Right ventricle: 25/00
P2 Channel Selections Arterial: 120/80 Radial artery: 120/80 Left ventricle: 120/00 Right atrium (Central Venous): 15/10 Right ventricle: 25/00 Pulmonary artery: 25/10 Pulmonary wedge: 10/2 Left atrium: 14/4
RS-232 RS-232 bi-directional interface 9600 Baud
Power 9 V alkaline battery
Dimensions 6.1" x 3.7" x 1.3" (15.6 cm x 9.4 cm x 3.4 cm)
Weight 0.9 lb (0.4 kg)
|
|

|
|