"NEW" Fluke PS410 ECG/Arrhythmia Simulator

Price: Add to Cart to View Pricing.
Item Number: PS410
WARRANTY: One year manufacturer warranty
SALES LEAD TIME: 14-21 Days
ACCESSORIES:User Manual, Battery Eliminator 100VAC to 240VAC to 9V
 
OVERVIEW:
 
The PS410 ECG/Arrythmia Simulator is a compact, high-performance simulator for patient monitor testing. This handheld device simulates a full range of cardiac rhythms and a wide variety of ECG conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms. Small enough to fit in a pocket, the handy PS410 weighs less than a pound and is easy to operate. Technicians simply connect the simulator to the device under test and use the PS410 keypad to enter the code presets. The simulator then transmits the selected preset simulations to the device.
 
FEATURES:
  • Compact, lightweight, pocket-sized
  • Easy top-panel control
  • 12-lead ECG
  • Adult and pediatric normal-sinus rhythms
  • 35 arrhythmia selections
  • ECG performance waveforms
  • ST segment levels
  • Pacemaker simulation
  • ECG artifact
  • Battery operated
SPECIFICATIONS
Normal Sinus Rhythm
   12-lead with independent outputs referenced to RL
Normal Rate:  80 BPM
Selectable Rates:  30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM
Accuracy:  + 1 %
Output Impedance:  940 Ω between leads
ECG Amplitudes:  0.5 mV, 1 mV, and 2 mV
Amplitude Accuracy:  + 2 % Lead II
High-Level Output:  1000x Lead II
Waveform Types:  Adult or Pediatric ECG Waveform

ECG Performance
Lead II
Square Wave:  2 Hz, 0.125 Hz
Pulse:  30, 60, 120 BPM; 60 ms pulse width
Sine Waves:  0.5, 5, 10, 40, 50, 60 Hz (1 mV amplitude only, lead II)
Triangle Wave:  2 Hz

ST Segment Analysis
Elevated or depressed:
   0.6 mV to 6 mV in 0.2 mV steps

 

Selections
Pacemaker
   Pacemaker rhythm
   Pacer non-capture*
   Pacer non-function
   Demand pacer with occasional sinus
   Demand pacer with frequent sinus
   A-V sequential
Artifact
   50 Hz artifact
   60 Hz artifact
   Muscle artifact
   Baseline artifact
   Respiration artifact
Arrhythmia
   PVC1 Left Ventricular Focus*
   PVC1 Early, LV Focus*
   PVC1 R on T, LV Focus*
   Pair of PVCs*
   Run of 5 PVCs*
   Run of 11 PVCs*
   Multi-focal PVCs*
   Frequent multi-focal PVCs*
   PVC2 Right Ventricular Focus*
   PVC2 Early, RV Focus*
   PVC2 R on T, RV Focus*
   Bigeminy
   Trigeminy
   PVCs at a rate of 6 per minute
   PVCs at a rate of 12 per minute
   PVCs at a rate of 12 per minute
   Ventricular Tachycardia
   Ventricular Fibrillation
   Ventricular Fibrillation 1/2 size
   Supraventricular Tachycardia
   Premature atrial contraction*
   Premature nodal contraction*
   Asystole
   Missed beat*
   Nodal Rhythm
   Irregular Rhythm
   Atrial flutter
   Atrial fibrillation
   Atrial fibrillation 1/2 size
   Atrial Tachycardia
   First-Degree Block
   Second-degree block
   Third-degree block
   Right-bundle-branch block
   Left-bundle-branch block
   * Event occurs once. To repeat, enter the selection again

Operation
 
   Outputs are easily selected or adjusted using top-panel controls and the large two-digit numeric display.

Controls
Display:
   2-line LCD
Control:
   6 control keys; ON/OFF power switch

General Information
Power:
   9 V battery/battery eliminator
Housing:
   ABS plastic case
Dimensions
   6.1 in L x 3.7 in W x 1.3 in H (11.3 cm L x 7 cm W x 3.4 cm H)
Weight:
   0.9 lb (0.4 kg)
Temperature:
   Operating: 59 ˚F to 95 ˚F (15˚C to 35 ˚C)
   Storage: 32 ˚F to 122 ˚F (0 ˚C to 50 ˚C)

 