"NEW" Fluke PS410 ECG/Arrhythmia Simulator
|
Price: Add to Cart to View Pricing.
Item Number: PS410
|
WARRANTY: One year manufacturer warranty
SALES LEAD TIME: 14-21 Days
ACCESSORIES:User Manual, Battery Eliminator 100VAC to 240VAC to 9V
OVERVIEW:
The PS410 ECG/Arrythmia Simulator is a compact, high-performance simulator for patient monitor testing. This handheld device simulates a full range of cardiac rhythms and a wide variety of ECG conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms. Small enough to fit in a pocket, the handy PS410 weighs less than a pound and is easy to operate. Technicians simply connect the simulator to the device under test and use the PS410 keypad to enter the code presets. The simulator then transmits the selected preset simulations to the device.
FEATURES:
-
Compact, lightweight, pocket-sized
-
Easy top-panel control
-
12-lead ECG
-
Adult and pediatric normal-sinus rhythms
-
35 arrhythmia selections
-
ECG performance waveforms
-
ST segment levels
-
Pacemaker simulation
-
ECG artifact
-
Battery operated
| SPECIFICATIONS
|
| Normal Sinus Rhythm
|
|
|
12-lead with independent outputs referenced to RL
|
| Normal Rate:
|
80 BPM
|
| Selectable Rates:
|
30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM
|
| Accuracy:
|
+ 1 %
|
| Output Impedance:
|
940 Ω between leads
|
| ECG Amplitudes:
|
0.5 mV, 1 mV, and 2 mV
|
| Amplitude Accuracy:
|
+ 2 % Lead II
|
| High-Level Output:
|
1000x Lead II
|
| Waveform Types:
|
Adult or Pediatric ECG Waveform
|
|
| ECG Performance
|
| Lead II
|
| Square Wave:
|
2 Hz, 0.125 Hz
|
| Pulse:
|
30, 60, 120 BPM; 60 ms pulse width
|
| Sine Waves:
|
0.5, 5, 10, 40, 50, 60 Hz (1 mV amplitude only, lead II)
|
| Triangle Wave:
|
2 Hz
|
|
| ST Segment Analysis
|
| Elevated or depressed:
|
|
|
0.6 mV to 6 mV in 0.2 mV steps
|
|
| Selections
|
| Pacemaker
|
|
|
Pacemaker rhythm
|
|
|
Pacer non-capture*
|
|
|
Pacer non-function
|
|
|
Demand pacer with occasional sinus
|
|
|
Demand pacer with frequent sinus
|
|
|
A-V sequential
|
|
| Artifact
|
|
|
50 Hz artifact
|
|
|
60 Hz artifact
|
|
|
Muscle artifact
|
|
|
Baseline artifact
|
|
|
Respiration artifact
|
|
| Arrhythmia
|
|
|
PVC1 Left Ventricular Focus*
|
|
|
PVC1 Early, LV Focus*
|
|
|
PVC1 R on T, LV Focus*
|
|
|
Pair of PVCs*
|
|
|
Run of 5 PVCs*
|
|
|
Run of 11 PVCs*
|
|
|
Multi-focal PVCs*
|
|
|
Frequent multi-focal PVCs*
|
|
|
PVC2 Right Ventricular Focus*
|
|
|
PVC2 Early, RV Focus*
|
|
|
PVC2 R on T, RV Focus*
|
|
|
Bigeminy
|
|
|
Trigeminy
|
|
|
PVCs at a rate of 6 per minute
|
|
|
PVCs at a rate of 12 per minute
|
|
|
PVCs at a rate of 12 per minute
|
|
|
Ventricular Tachycardia
|
|
|
Ventricular Fibrillation
|
|
|
Ventricular Fibrillation 1/2 size
|
|
|
Supraventricular Tachycardia
|
|
|
Premature atrial contraction*
|
|
|
Premature nodal contraction*
|
|
|
Asystole
|
|
|
Missed beat*
|
|
|
Nodal Rhythm
|
|
|
Irregular Rhythm
|
|
|
Atrial flutter
|
|
|
Atrial fibrillation
|
|
|
Atrial fibrillation 1/2 size
|
|
|
Atrial Tachycardia
|
|
|
First-Degree Block
|
|
|
Second-degree block
|
|
|
Third-degree block
|
|
|
Right-bundle-branch block
|
|
|
Left-bundle-branch block
|
|
|
* Event occurs once. To repeat, enter the selection again
|
|
| Operation
|
|
|
|
|
Outputs are easily selected or adjusted using top-panel controls and the large two-digit numeric display.
|
|
| Controls
|
| Display:
|
|
| Control:
|
|
|
6 control keys; ON/OFF power switch
|
|
| General Information
|
| Power:
|
|
|
9 V battery/battery eliminator
|
|
| Housing:
|
|
| Dimensions
|
|
|
6.1 in L x 3.7 in W x 1.3 in H (11.3 cm L x 7 cm W x 3.4 cm H)
|
|
| Weight:
|
|
| Temperature:
|
|
|
Operating: 59 ˚F to 95 ˚F (15˚C to 35 ˚C)
|
|
|
Storage: 32 ˚F to 122 ˚F (0 ˚C to 50 ˚C)
|
|
|
|

|
|