PREOWNED Fluke IDA5/4 Four-channel Infusion Device Analyzer, US

PREOWNED Fluke IDA5/4 Four-channel Infusion Device Analyzer, US
PREOWNED Fluke IDA5/4 Four-channel Infusion Device Analyzer, US PREOWNED Fluke IDA5/4 Four-channel Infusion Device Analyzer, US PREOWNED Fluke IDA5/4 Four-channel Infusion Device Analyzer, US
$4,995.00
Ex Tax: $4,995.00
Brand: Fluke Biomedical
Product Code: Fluke Biomedical IDA 5/4
Availability: In Stock
WARRANTY: One Year Warranty (PREOWNED UNIT)
SALES LEAD TIME: 14 DAYS
ACCESSORIES INCLUDED: Drain Tubing, 3 way stopcocks, power cord
DATA SHEET: https://www.flukebiomedical.com/sites/default/files/resources/IDA-5_ENG_E_W.PDF
USER MANUAL: https://www.flukebiomedical.com/sites/default/files/resources/ida5_umeng0200.pdf
 
KEY FEATURES:
  • Compatible with virtually any type of infusion device
  • Tests up to four infusion pumps at the same time
  • Customizable test templates for quick and standardized infusion device testing
  • Real-time snapshots of flow and pressure for immediate issue recognition
  • Convenient and easy data entry with plug-n-play, USB compatible, keyboard or barcode scanner
  • Instantaneous and average flow measurement of up to 1500 ml/hr
  • Single-flow, dual-flow (piggyback) and PCA testing
  • Auto-start mode enables unit to begin testing only when fluid is detected to maximize accuracy
  • Ability to automatically end flow measurement based on user-defined time, volume or both
  • Compatible with a wide variety of off-the-shelf printers
  • Built-in memory to save test results for printing or downloading to computer
  • Optional automation software completely integrates medical device testing including electrical safety, visual inspection and other performance parameters for total digital data management
  • Tethers with other Fluke Biomedical automated test devices for harmonized workflow and reporting
  • Global support network delivers prompt service to Fluke Biomedical customers worldwide
 
TECHNIQUE, RANGE, ACCURACY, MAX TEST DURATION
 
Flow rate measurement
Flow is calculated by measuring volume over time 0.5 ml/h to 1000 ml/h
1 % of reading ± 1 LSD for flows of 16 ml/h to 200 ml/h for volumes over 20 ml, otherwise 2 % of reading ± 1 LSD for volumes over 10 ml under laboratory conditions. 10 hours on battery
 
Volume measurement
Volume measured directly by the measuring module in minimum sample sizes of 60 microliters 0.06 ml to 999 ml 1 % of reading ± 1 LSD for flow rates of 16 ml/h to 200 ml/h for volumes over 20 ml. Otherwise 2 % of reading ± 1 LSD for volumes over 10 ml under laboratory conditions. 10 hours on battery
 
Pressure measurement
Direct measurement of pressure at the inlet port 0 psi to 45 psi or equivalent in mmHg and kPa 1 % of full scale ± 1 LSD under laboratory conditions 30 minutes
 
General specifications
 
Storage of Results
Test results stored for later viewing, printing or transfer to PC. Typical practical capacity: 100 tests
 
Power Down
The results of tests in progress will be saved in the case of accidental power down
 
Computer Control
The Product can be fully controlled from a PC using HydroGraph V3 software for IDA-1S
 
Battery Power
4 x Panasonic HHR210AB NiMh 2000 mAh batteries
 
Dimensions
30 cm x17 cm x 10 cm (12 in x 8 in x4 in)
 
Weight
~1.2 kg (2.7 lbs)
 
Safety
IEC 61010-1: Overvoltage category II, Pollution Degree 2
 
Electromagnetic Environment
IEC 61326-1: Basic
 
Emissions Classification
IEC CISPR 11: Group 1, Class A.
Group 1 have intentionally generated and/or use conductively coupled radio-frequency energy which is necessary fpr the internal functioning of the equipment itself.
Class A equipment is suitable for use in nondomestic locations and/or directly connected to a low-voltage power supply network
 
FCC
CFR47: Class A Part 15 subpart B
 
Electromagnetic Compatibility
Applies to use in Korea only. Class A: Equipment (Industrial Broadcasting and Communication Equipment)¹
 
Altitude
0 m to 2000 m (0 ft to 6500 ft)
 
Temperature
15 ° C to 30 ° C (59 ° F to 86 ° F)
-20 ° C to +40 ° C (-4 ° F to +104 ° F) when drained of all liquid
 
Humidity
10 % to 90 % non-condensing
 
Charger
Operating voltage range:
100V ac to 240V ac
 
Supply frequency:
50Hz / 60 Hz Supply power: <20 VA