Welcome visitor you can login or create an account.

Currency: US Dollar

BIOMEDEQUIP, INC.

0 item(s) - $0.00

Your shopping cart is empty!

PREOWNED Fluke DPM4-2G Parameter Tester

PREOWNED Fluke DPM4-2G Parameter Tester
PREOWNED Fluke DPM4-2G Parameter Tester PREOWNED Fluke DPM4-2G Parameter Tester
$1,195.00
Ex Tax: $1,195.00
Brand: Fluke Biomedical
Product Code: DPM4-2G
Availability: In Stock
THIS IS A PREOWNED UNIT AND IS BEING SOLD AT 50% off LIST PRICE
 
SALES LEAD TIME: 5-7 DAYS
WARRANTY: One Year
ACCESSORIES: Soft Carrying Case, Battery Eliminator, Operator Manual
 
OVERVIEW: 
  • Palm size
  • High accuracy
  • Differential pressure, vacuum, and temperature measurements
  • Multiple user-selectable units of measurement
  • Simultaneous display of multiple parameter measurements
  • Leak detection/leak-rate calculation
  • RS232 for computer control
  • Pressure measurements from -700 mmHg to +5000 mmHg range (applies to the 1G and 2G models only)
  • Barometric-pressure, flow, and humidity measurements (applies to the 2G and 2H models only)
 
 
 
SPECIFICATIONS: 
Pressure Measurement
DPM4 Model 1H or 2H
Operating range: -350 mmHg to 350 mmHg
Accuracy: ± 0.3 % of range
Resolution: 0.1 mmHg
Units of measure: mmHg, mBar, cmH2O, PSI, InHg, InH2O, kgcm2 and kPa
DPM4 Model 1G or 2G
Operating range: -700 mmHg to 5000 mmHg
Accuracy: 0.3 % of range for temperatures from 21 ºC to 25 °C and relative humidity from 30 % to 70 %; 0.3 % of range plus 0.02 % of range per degree C for temperature < 21 °C or > 25 °C with relative humidity from 30 % to 70 %
Resolution: 0.5 mmHg
Units of measure: mmHg, mBar, cmH2O, PSI, InHg, InH2O, kgcm2 and kPa

 

Temperature Measurement
All Models (DPM4-1H, 1G, 2H, 2G)
Operating range: -40 ºC to 200 ºC
Accuracy: ± (2 % of reading, 0.5 ºC)
Resolution: 0.1 °C and °F
Units of measure: °C and °F
  Use standard external temperature probe type PT-100 or PT-1000 (DIN/IEC 751 Class A) for temperature measurements in °C or °F
Temperature Probe Specification
   
PT-100
Operating range: -50 ºC to +200 ºC
Accuracy: ± 0.23 ºF @ 212 ºF (0.13 ºC @ 100 ºC)
± 0.18 ºF @ 32 ºF (0.1 ºC @ 0 ºC)
± 0.36 ºF @ 212 ºF (0.2 ºC @ 100 ºC)
PT-1000
Operating range: -50 ºC to +200 ºC
Accuracy: 0.3 ºC (0.5 ºF)

 

Barometric Pressure
DPM4 Model 2G or 2H
  It is possible to compensate for the sea level and calibrate for offsets.
Operating range: 380 mmHg to 825 mmHg
Accuracy: 2 % of reading ±1LSD
Resolution: 0.1 mmHg
Units of measure: mmHg, mBar, inHg and hPa

 

Gas Flow
DPM4 Model 2G or 2H
  Measures with an embedded sensor with 11 calibration points to compensate nonlinearity. Calibration constants stored in firmware.
Operating range: -750 to 750 ml/min
Accuracy: 1% of range or 5% of reading, whichever is greatest
Resolution: 0.1 ml/min
Compatibility: Gas: Air, N2, O2, CO, NO, CO2, N2O, and NO2
Units of measure: ml/min (or SCCM - Standard Cubic Centimeters per Minute)

 

Relative Humidity
DPM4 Model 2G or 2H
  An integrated sensor in the instrument determines relative humidity measurements.
Operating range: 12 % to 95 % RH
Accuracy: 3.5 % of reading ± 2 % RH @ 25 ºC for RH between 12 % and 95 % RH
Resolution: 0.1% RH
Gas compatibility: Air
Units of measure: % RH

 

General Information
 
Temperature Requirements: 15°C to 35°C when operating 0°C to 50°C in storage
Display/Control: LCD graphic display, 128 x 32 pixel
Data Input/Outputs (1): Bi-directional RS-232C for Computer control
Power: 9 Volt Alkaline Battery RG9 or Battery eliminator
Case: ABS plastic case
Weight: 0.4 kg / 0.9 lbs. with battery
Dimensions: D x W x H:
  34 mm x 94 mm x 156 mm
  1.3 in x 3.7 in x 6.1 in