Fluke PS410 ECG/Arrhythmia Simulator

Fluke PS410 ECG/Arrhythmia Simulator
Call for Price
Product Code: Fluke PS410 ECG/Arrhythmia Simulator
Availability: In Stock


 

WARRANTY: One year warranty
SALES LEAD TIME: 14-21 Days
ACCESSORIES: User Manual, Battery Eliminator 100VAC to 240VAC to 9V
 
OVERVIEW: 
The PS410 ECG/Arrythmia Simulator is a compact, high-performance simulator for patient monitor testing. This handheld device simulates a full range of cardiac rhythms and a wide variety of ECG conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms. Small enough to fit in a pocket, the handy PS410 weighs less than a pound and is easy to operate. Technicians simply connect the simulator to the device under test and use the PS410 keypad to enter the code presets. The simulator then transmits the selected preset simulations to the device.
 
FEATURES:
Compact, lightweight, pocket-sized
Easy top-panel control
12-lead ECG
Adult and pediatric normal-sinus rhythms
35 arrhythmia selections
ECG performance waveforms
ST segment levels
Pacemaker simulation
ECG artifact
Battery operated

 

SPECIFICATIONS

Normal Sinus Rhythm

 

 12-lead with independent outputs referenced to RL

Normal Rate:

 80 BPM

Selectable Rates:

 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM

Accuracy:

 + 1 %

Output Impedance:

 940 Ω between leads

ECG Amplitudes:

 0.5 mV, 1 mV, and 2 mV

Amplitude Accuracy:

 + 2 % Lead II

High-Level Output:

 1000x Lead II

Waveform Types:

 Adult or Pediatric ECG Waveform

ECG Performance

Lead II

Square Wave:

 2 Hz, 0.125 Hz

Pulse:

 30, 60, 120 BPM; 60 ms pulse width

Sine Waves:

 0.5, 5, 10, 40, 50, 60 Hz (1 mV amplitude only, lead II)

Triangle Wave:

 2 Hz

ST Segment Analysis

Elevated or depressed:

 

 0.6 mV to 6 mV in 0.2 mV steps

Selections

Pacemaker

 

 Pacemaker rhythm

 

 Pacer non-capture*

 

 Pacer non-function

 

 Demand pacer with occasional sinus

 

 Demand pacer with frequent sinus

 

 A-V sequential

Artifact

 

 50 Hz artifact

 

 60 Hz artifact

 

 Muscle artifact

 

 Baseline artifact

 

 Respiration artifact

Arrhythmia

 

 PVC1 Left Ventricular Focus*

 

 PVC1 Early, LV Focus*

 

 PVC1 R on T, LV Focus*

 

 Pair of PVCs*

 

 Run of 5 PVCs*

 

 Run of 11 PVCs*

 

 Multi-focal PVCs*

 

 Frequent multi-focal PVCs*

 

 PVC2 Right Ventricular Focus*

 

 PVC2 Early, RV Focus*

 

 PVC2 R on T, RV Focus*

 

 Bigeminy

 

 Trigeminy

 

 PVCs at a rate of 6 per minute

 

 PVCs at a rate of 12 per minute

 

 PVCs at a rate of 12 per minute

 

 Ventricular Tachycardia

 

 Ventricular Fibrillation

 

 Ventricular Fibrillation 1/2 size

 

 Supraventricular Tachycardia

 

 Premature atrial contraction*

 

 Premature nodal contraction*

 

 Asystole

 

 Missed beat*

 

 Nodal Rhythm

 

 Irregular Rhythm

 

 Atrial flutter

 

 Atrial fibrillation

 

 Atrial fibrillation 1/2 size

 

 Atrial Tachycardia

 

 First-Degree Block

 

 Second-degree block

 

 Third-degree block

 

 Right-bundle-branch block

 

 Left-bundle-branch block

 

 Event occurs once. To repeat, enter the selection again

 

Operation

 

 

 Outputs are easily selected or adjusted using top-panel controls and the large two-digit numeric display.

 

Controls

Display:

 

 2-line LCD

Control:

 

 6 control keys; ON/OFF power switch

 

General Information

Power:

 

 9 V battery/battery eliminator

Housing:

 

 ABS plastic case

Dimensions

 

 6.1 in L x 3.7 in W x 1.3 in H (11.3 cm L x 7 cm W x 3.4 cm H)

Weight:

 

 0.9 lb (0.4 kg)

Temperature:

 

 Operating: 59 ˚F to 95 ˚F (15˚C to 35 ˚C)

 

 Storage: 32 ˚F to 122 ˚F (0 ˚C to 50 ˚C)