Welcome visitor you can login or create an account.

Currency: US Dollar

BIOMEDEQUIP, INC.

0 item(s) - $0.00

Your shopping cart is empty!

Pronk Technogies SC-5 Mini NIBP Tester

Pronk Technogies SC-5 Mini NIBP Tester
Call for Price
Brand: Pronk Technologies
Product Code: Pronk Technologies SC-5 Mini NIBP Tester
Availability: In Stock

WARRANTY: Four year Manufacturer warranty
SALES LEAD TIME: 10-14 Day.
ACCESSORIES INCLUDED:  One Tubing Adapter, AC Adapter, Operator Manual, Calibration Certificate

FUNCTIONS INCLUDE: NIBP, IBP, Arrhythmia, ECG, Pacer, Resp, Peak Detect, Alarm Test, Leak Detect

DESCRIPTION:
The SimCube SC-5 combines the functions of both a manometer (pressure gauge) and an NIBP simulator.  The SC-5 NIBP function has five modes:  Manometer (+/- 400mmHg), Adult (120/80 mmHg), Neonatal (70/40 mmHg), Hypertensive (190/120 mmHg), and Hypotensive (80/40 mmHg).  A single button toggles through each of the modes. A mini-DIN connector provides access to 3 dynamic IBP values (120/80, 70/40, 190/120) and 7 static IBP values (0, 25, 50, 100, 150, 200, 250). Ten snaps provide 3-, 5-, or 12-lead electrocardiogram (ECG) simulation at 3 heartrates (70, 95, Asystole) plus a Heartrate sequence, as well as Arrhythmia, Pacer, and 3 Resp rates with a Resp Sequence. An Alarm Test mode toggles the ECG Heart Rate and Respiration values between 47/00 bpm and 160/80 bpm every 30s.  Peak Detect (Overpressure) measurement and Leak Rate measurement functions are provided. The SC-5 is compatible with the Battery Boost Option.

TECHNICAL SPECIFICATIONS:

Physical Dimensions: Size 3”x 3” x 3.5” (7.6cm X 7.6cm  X 8.9cm) 
Weight: 2.5 Lbs 
Power External A/C Adaptor: (Output: 6VDC / 2amps, 2.1mm, center positive connector) or 4 AA Batteries (with Battery Boost Option) 
NIBP Connection: Quick Disconnect, Female 
ECG/Resp Connection : 10 ECG snaps 
IBP Connection:  Mini-DIN  
Manometer Range:  – 400 to + 400 mmHg 
Precision:  0.1 mmHg 
Accuracy:  +/- 1 mmHg 
User Interface: Single Button Operation 

OPERATING MODES:
Adult NIBP, Neo NIBP,  Hypertensive NIBP,  Hypotensive NIBP,  Manometer,  Peak Detect,  HR Seq.,  Alarm Test, ECG Pace ON, Arrhythmia Sequence,  Heart Rate Sequence,  Invasive BP,  Zero Invasive BP,  100, 200 Invasive BP Sequence 
 

NIBP Adult Simulation:   
Simulated Pressure: 120/80 (97) mmHg 
Simulated Heart Rate  70 bpm 
Simulated Pulse Volume 1 ml

NIBP Neonatal Simulation    
Simulated Pressure: 70/40 (52) mmHg 
Simulated Heart Rate:  95 bpm 
Simulated Pulse Volume: 0.25 ml

NIBP Hypertensive Simulation    
Simulated Pressure: 190/120 (146) mmHg 
Simulated Heart Rate:  70 bpm 
Simulated Pulse Volume: 1 ml

NIBP Hypotensive Simulation    
Simulated Pressure: 80/40 (58) mmHg 
Simulated Heart Rate:  70 bpm 
Simulated Pulse Volume: 1 ml

ECG Simulation   
Isolated: Yes 
Synchronized with NIBP: Yes 
R Wave Size: 1mV (lead I) +/- 5% 
R Wave Width: 35 ms 
Wave Shape:  QRS wave 
Connection : 10 Snaps 
Simulation Rates:  70, 95, Asystole, Arrhythmia, Pacer, HR seq. 
HR Sequence:  30 seconds each of:30, 60, 90, 120, 45, 160, and 220 bpm

Pacer Simulation    
Isolated:Yes 
Synchronized with NIBP:  Yes 
Pacer Size:  3 mV 
Pacer Width : 1.2 ms

Respiration Simulation    
Isolated : Yes 
Synchronized with NIBP: Yes 
Wave Shape:  Square Wave 
Size:  4 Ohm 
Simulation rates:  20, 40, Apnea, Sequence = 00, 30, 45, 60, 22, 30, 80, 110.

Arrhythmia Simulation   
 Cardiac failure sequence: ~ 90 seconds of normal beats interspersed with PVCs and Runs, followed by ~30 seconds of VTAC, followed by ~30 seconds of VFIB, concluding with ~30 seconds of asystole.  
  
Peak Detect   
Precision 1.0mmHg 
  
Invasive Blood Pressure Simulation   
Isolated: Yes 
Synchronized with NIBP: Yes 
Excitation Voltage DC range = 3.3 to 5.8 AC range = 3.3 to 12p-p 
Pressure range: 0-250 mmHg 
Simulated Pressure accuracy: +/- 1 mmHg 
Wiring + Excit = pin 1, - Excit = pin 4, + Sig = pin 3, -Sig = pin 6 
Simulation rates Dynamic = 120/80, 70/40, 190/120. Static = 0, 100, 200. Step = 0,25,50,100,150,200, 250

Environmental    
Voltage Range: 100-240 VAC, 50-60 Hz